pdf factors contributing to large diameter water pipe

Effects of Water Age on Distribution System Water Quality

water only. Recommended Standards for Water Works (Ten State Standards, 1997) specify a minimum pipe size of six inches at all locations for providing fire protection. Table 2 shows the volumetric effect of increased pipe diameter on a per-mile basis. Table 2 Pipe diameter vs. Pipe Volume (per mile) Pipe Diameter 2 4 6 8 10 12 Engineering & Design DataWhere:f = friction head of feet of water per 100' for the specific pipe size and I.D. C = a constant for internal pipe roughness. 150 is the commonly accepted value for PVC and CPVC pipe. G = flow rate of gallons per minute (U.S. gallons). di = inside diameter of pipe in inches. Nominal Size 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 4 6 8 10 12

Evaluating Dynamic Loads in Piping - Pipe Flow Software

Figure 4 shows the model used for this example. The total pipe length of 1080 feet is 20 diameter, standard wall thickness, flowing water at 60 F. The transient event is the partial closure of valve J2, from 100% flow to 10% flow over 2 seconds, with a Cv profile as shown in Figure 5. Factors Affecting Line Sizing of Piping or Pipeline Step 1 Assume line size. Step 2 Calculate velocity by. V = Q / (Flow Area) Step 3 Calculate the pressure drop by the proper method. Step 4 Check whether calculated velocity & pressure drop falls within recommended ranges. If YES then select the line size; If NO then selects a new line size and repeat steps 2 to 4. Flow in Systems with Multiple PipesPoint Elevation (ft) Pipe Length (ft) Diameter (in) Friction factor E 150 1 1200 8 0.035 A 120 2 800 6 0.025 B 70 3 900 4 0.045 C 60 4 500 6 0.025 D 30 Solution. (a) The general principles that we will apply are that the headloss must be identical

How to Determine Suitable Pipe Sizes for Water

The loss of pressure of outlets placed above water source. Loss of pressure is commonly caused by friction of water. The friction is occurred due to flow of water in pipes, water flow meter, and backflow preventer. Restriction on water flow velocity to avoid noises and pipe erosion. Extra capacity of possible expansion in the future. Identifying Factors that Influence the Factor of Safety Jan 01, 2015 · Cast iron water mains comprise approximately 28%, by length, of all water mains in Canada and the United States. Many of these cast-iron water mains are reaching the end of their expected service lives and their rate of failure is increasing. Of particular concern are large-diameter water mains, for which the consequences of failure can be severe. Pipe Dimensions & Weights Chart - SnowCrestPipe Dimensions This table lists the outside & inside diameter, wall thickness and internal area for a wide range of commercial pipe sizes. The Internal Area can be used to calculate velocities of fluids. These dimensions apply to carbon, stainless steel, PVC and seamless pipe.

Pipe Failure Analysis and Impact of Dynamic Hydraulic

Jan 01, 2015 · Temperature:A reduction in temperature can contribute to pipe failures through volume expansion of water, frost heave in the soil surrounding the pipe, and increased brittleness. Various factors such as intensity and duration of cold weather, rate of freezing, surface cover, mains depth, etc. might affect the development of frost-heave. Selecting the Optimum Pipe Size - PDHonlineWater pipes were made of bored-out logs, felled from hemlock or elm trees. The trees were cut into seven-to-nine-foot lengths, with trunks to build large scale waterworks as it drew upon the ample supply of the Schuykill River.3 optimum pipe size is confused to be limited to mean most economic pipe size. Water Distribution System Challenges And SolutionsSep 09, 2014 · Leaks on large diameter pipes are always difficult to detect and often specialized equipment is required (e.g., inside pipe inspection and leak detection). These techniques are costly but might be economically well justified where water availability is limited and every cubic meter of water recovered can be sold to existing or new customers.

Water Pipeline Design Guidelines - Sask H2O

and size of pipe, and location of hydrants, valves and appurtenances, backflow prevention, flushing The single most important factor for determining the efficiency of a disinfectant in a water pipeline is the CT factor. Disinfection with chlorine requires time. The CT factor is defined as the residual disinfectant concentration (C in mg/L Influence of Pipe-Diameter on Water Hammer pipe-diameter. The possible influence of pipe diameter on pressure-wave cycles-number had been analyzed too, and it was founded an inverse relation between them. 2. Model Formulation The analysis of water hammer was done under the following assumptions:One-dimensional flow; The pipe is water fulfill and remains at this